AC Line/Load Reactors / MTE Corporation
 |
AC Line/Load Reactors
Description:
MTE line/load reactors help keep your equipment running longer by absorbing many of the power line disturbances which otherwise damage or shut down your inverters, variable speed controllers, or other sensitive equipment. They are the modern technology solution to inverter and drive application problems. MTE reactors are harmonic compensated and IGBT protected to assure optimum performance in the presence of harmonics. They are very effective at reducing harmonics produced by inverters and drives, and in most cases will help you to meet IEEE 519. Use our harmonic compensated reactors on either the input or output of an adjustable speed drive/inverter. There is no need to derate our "harmonic compensated" reactors for harmonics. It Features:
- Increase Drive System Reliability
- Filter Power Line Disturbances
- Reduce Harmonics
- Reduce Surge Currents
- Reduce dv/dt
- Extend Transistor Life
- Reduce Motor Noise and Temperature
- Reduce Voltage Doubling Effects
- Improve True Power Factor
- Absorb Power Line Spikes
- Protect Motors from Long Lead Effects
- Reduce Output Voltage dv/dt
- Virtually Eliminate Nuisance Tripping
- Extend Semiconductor Life
- Reduce Harmonic Distortion
- Reduce Surge Currents
- Reduce Motor Temperature
- Reduce Motor Audible Noise
- Improve True Power Factor
- Helps Meet IEEE 519 or EN 61000-3-4
Technical Specs :
|
Standard impedance values
|
1-1/2%, 2, 3%, 4%, 5% available
|
|
Impedance basis
|
Reactor fundamental current rating
|
|
Service Factor (Continuous)
Reactors rated 1 to 750 Amps
Reactors rated above 750 Amps
|
150% of fundamental rating
125% of fundamental rating minimum
Note: Select reactor based on fundamental current rating
|
|
Overload Rating
|
200% of fundamental for 30 minutes 300% of fundamental for 1 minute
|
|
Maximum system voltage
|
600 Volts ( units with terminal blocks) 690 Volts (units with box lugs or tab terminals)
|
|
Maximum switching frequency
|
20 KHz
|
|
Insulation system
|
Class N (200° C)
|
|
Temperature rise
|
135° C (average) Open or enclosed reactors
|
|
Ambient temperature
|
45° C (maximum) Open or enclosed reactors
|
|
Altitude (maximum)
|
1000 meters
|
|
Fundamental frequency
|
50/60 Hz Line or Load
|
|
Approvals:
|
CE, UL-508, CSA C22.2
|
|
Inductance curve (typical)
|
100% at 100% current 100% at 150% current 50% at 350% current (minimum)
|
|
Inductance tolerance
|
+/- 10%
|
|
Impregnation:
|
High Bond Strength “Solvent less” Epoxy, 200° C UL94HB recognized
|
|
Dielectric Strength
|
3000 volts rms (4243 volts peak)
|
|
dv/dt Protection
|
Meets NEMA MG-1, part 31 (same as inverter duty motors)
|
|
Protection:
|
Open reactors with terminal blocks through 45 amps meet IP20
|
» Link for PDF file (185 kb) |
|